Material Mild Steel Drawing No. 678
Stage After Welding Surface Condition As Welded
Technique Electromagnetic Yoke-DC Type
Product Make and Product Code Batch No. Expiry Date
Examination Medium Black Ready Bath P7855 20-Oct-2020
Contrast Paint - P7855 20-Oct-2020
Bath Medium Water - 13-Dec-2099
Test Equipment Used - Lifting Weight with Certificate No. 5.5 Kg(I/6075/P)
Type of Current and Pole Spacing AC Type 4-6 inches Magnetization Method Longitudinal Magnetisation in 2 directions
Application of Bath Medium By Spraying Method of Bath Application Wet Continuous
Concentration of Bath (for Non-Fluroscent Medium) 1.3 ml per 100 ml Bath / Powder Contamination Check Found OK
Lighting Equipment LED Torch Lux Meter Sr. No: 17519965, Validity: 04-Jan-2026
Light Intensity 1100 micro Watt/cm2 UV Meter Sr. No: DUVT-5K-0534, Validity: 25-Nov-2025
Field Adequacy Ensured By Shim and known Discontinuity Sample Background White Light Intensity Less then 20 Lux for Fluroscent Medium
Part Surface Temperature 32 °C Thermometer Sr. No: 201807023992, Validity: 23-Jan-2026
Field Strength - Gauss Meter (30-60 Gauss) 30 Gauss Meter Sr. No: 19195/ GMCAL, Validity: 16-Dec-2025
Examination Extent 100% (Accessible Area Only)
Specification/Standard/Procedure ASTM
Acceptance Standard ASME Sec VIII Div.1 App. 8
OBSERVATION AND RESULTS
Sr. No. Description Qty Observation Evaluation
1 Weld Joint Tag A-876 2 No Record-able Indication Observed Acceptable
2 Weld Joint Tag 367 2 No Record-able indication observed Acceptable

Remark: Remark

Note:

 
ID - 7405 NDE (MT) REPORT REQ ID - 24-2
Client Alfa Manufacturing Company Report No. IBTS/MT/7405
Address Gala 1, Industrial Area Revision 6
Report Date 02-Aug-2025
Component MT Yoke Report Test Date 11-Dec-2021